ROUND ENGINEERING INC.

bolted cover FAILURE AT 1276 PSIG

When code calculations cannot be used to verify a product design burst testing is accordance with UG-101 of ASME Section VIII-1 may be performed.


Witnessing of Burst Tests must be performed by a National Board Inspector.


Round Engineering works with qualified laboratories to coordinate and perform burst testing. Test fixtures, if required, are designed and supplied by us.


Once testing is complete we evaluate the results in accordance with code requirements. Proof test reports and the associated calculations are then prepared for submission to the CRN jurisdiction.  

SANITARY PRESSURE VESSEL ASME BPE CLAMP FAILURE AT 1287 PSIG

services include

  • Burst testing up to 75,000 psig
  • Burst testing at temperatures between -30 F and 572 F.
  • Cycle pressure testing up a to rate of 20 Hz for short or extended periods of time.

test set up for burst testing a valve at a temperature of 572 f using dynalene 600 high temperature heat transfer fluid

CANADIAN REGISTRATION NUMBER CRN, PRESSURE VESSEL, PIPING AND VALVE ENGINEERS.

SWING BOLT COVER FAILURE AT 718 PSIG

ball valve failure at 3508 psig at a elevated temperature of 500F.

ASME burst TESTING